← SBrT2017
Melhorando a Identificação do Período Transiente em Simulações de Eventos Discretos
Discrete event simulationM/M/1 queueRWPwarm-up period
Resumo
Establishing the warm-up period is a recurrent
problem in discrete event simulation. The MSER-5 method for
transient detection is consolidated and one of most cited work in
the literature due to its simplicity and interesting results. This
work suggests adaptations in the method to achieve better error
rates and execution times. These suggestions are also applied to
a variant of this method, the MSER-5Y, which is considered an
advancement over the original method. The results of present
work show that it is possible to achieve better results compared
to MSER-5 and at least match MSER-5Y’s performance using
far less execution times with minor adaptations.